This is a continuation of Getting rid of DICOM images in Python. The information is as of September 2017.
PyDicom now seems to have a version of 1.0.0a1 when downloaded from github.
_versions.py
"""Pure python package for DICOM medical file reading and writing."""
__version__ = '1.0.0a1'
__version_info__ = (1, 0, 0, 'alpha', 0)
However, it seems that pydicom that can be installed with conda-forge or PyPI is still 0.9.9. Since 1.0 and later, there are various changes, so the document also has a chapter called Transition to pydicom 1.x. For the time being, I will create this page in compliance with 0.9.9.
In the previous Getting rid of DICOM images with Python, Osirix's [DICOM Image Library](http: //) is the source of DICOM image samples. I introduced www.osirix-viewer.com/resources/dicom-image-library/), but now it seems that only Osirix users can access it.
For that reason, I would like to introduce the following two sources for obtaining DICOM image samples.
For the DICOM headers you know, you can display them as follows: What Modality is this image taken? It is displayed.
import dicom
dcm = dicom.read_file('CT_small.dcm')
print(dcm.Modality)
Also, if you just want to display everything in text, you don't need to do anything.
import dicom
dcm = dicom.read_file('CT_small.dcm')
print(dcm)
So what if you want to print all the headers (but not the images) like this `` `print (dcm) ```? So, I tried to chase the source code a little.
Then there was a hint in pydicom / dataelem.py.
dataelem.py
def __str__(self):
"""Return str representation of the element."""
repVal = self.repval
if self.showVR:
s = "%s %-*s %s: %s" % (str(self.tag), self.descripWidth,
self.description()[:self.descripWidth],
self.VR, repVal)
else:
s = "%s %-*s %s" % (str(self.tag), self.descripWidth,
self.description()[:self.descripWidth], repVal)
return s
Apparently, does the property `` `showVR``` show the data type of the DICOM header? It seems that it is a flag of.
What kind of VR is there? That's because you should definitely look at the DICOM Specifications (http://dicom.nema.org/dicom/2013/output/chtml/part05/sect_6.2.html).
With that in mind, if you just squeeze `__str__ ()`
of `` `dataelem.py``` as it is, all the metadata tags, names, types and displays will be listed in .append () It seems that you can get all the data by doing something like that.
import dicom
dcm = dicom.read_file('CT_small.dcm')
dcm_header_list = []
for data_element in dcm:
dcm_header = '{0}\t{1}\t{2}\n'.format(str(data_element.tag),
data_element.name,
data_element.repval)
dcm_header_list.append(dcm_header)
As described in Getting rid of DICOM images with Python, you can combine slices to create 3D data. Image data from DICOM files can be retrieved from pixel_array as a numpy array.
import os
import dicom
import numpy as np
dcm_list = []
for root_d, _, files in os.walk('BRAINIX'):
for f in files:
_, ext = os.path.splitext(f)
if ext == '.dcm':
dcm_list.append(os.path.join(root_d, f))
ref_dcm = dicom.read_file(dcm_list[0])
width = ref_dcm.Columns
height = ref_dcm.Rows
depth = len(ref_dcm)
img3d = np.zeros((depth, height, width),
dtype = ref_dcm.pixel_array.dtype)
for dcm_file in dcm_list:
idx = dcm_list.index(dcm_file)
dcm = dicom.read_file(dcm_file)
img3d[idx, :, :] = dcm.pixel_array()
As a result, DICOM image data is stored in a three-dimensional array called img3d. In order to visualize this, it is converted into a two-dimensional image using a method called MIP (Maximum Intensity Projection) or MinIP (Minimum Intensity Projection).
Which axis should be used to create a cross-sectional image of 3D image data? And which axis of pixels should be used as the representative value when creating a two-dimensional image along that axis? That being said, MIP uses the pixel with the highest brightness, and MinIP uses the pixel with the lowest brightness as a representative value.
Which cross section should be used for the human body? For that, each cross section has a name. Wikipedia article: Anatomical_plane
Whether you use the maximum value or the minimum value, you'll be able to use the numpy array from here.
#Omission
max0 = np.nanmax(img3d, axis=0)
max1 = np.nanmax(img3d, axis=1)
max2 = np.nanmax(img3d, axis=2)
In the case of the BRAINIX MRI image this time, axis = 0
corresponds to the Coronal Plane, so max0 stores the MIP image of the Coronal Plane. After that, `matplotlib.imshow ()`
, im = Image.fromarray (max0) `` `in PIL, then
im.show ()
I think it's OK.
Whether the cross section of the original image is axial, coronal, or sagittal seems to have to be judged from the original image, but if you make a 3D array like img3d
in this way, from which cross section It will also be possible to cut out.
In general, CT is imaged in the axial plane, so I think it is three-dimensional [axial, coronal, sagittal].
I wrote the continuation of Getting rid of DICOM images with Python.